Energy / Heat Recovery Ventilators / AHU’s

In Ceiling Energy Recovery Ventilator (ERV-IC) 
100 to 900 L/s

In Ceiling ERV is a fully ducted ventilator designed to ventilate any domestic, commercial or institutional building. It will remove stale air from the indoor air space and replace it with fresh air which has been pre-conditioned so as to have minimal impact on the indoor air temperature and humidity. By continuously ventilating the indoor space the ERV-IC deters the buildup of allergens, mould, dust mites and other chemical pollutants when the building is sealed providing a healthier living and working environment. 

The counter flow enthalpy heat exchanger will reclaim up to 75% of the energy from the exhaust air saving 75% of the cost to heat or cool the outdoor air to the internal temperature and condition.  In Ceiling Energy Recovery Ventilator (ERV-IC) - 100 to 900 litres per secondThe In Ceiling ERV is a fully ducted ventilator designed to ventilate any domestic, commercial or institutional building. It will remove stale air from the indoor air space and replace it with fresh air which has been pre-conditioned so as to have minimal impact on the indoor air temperature and humidity.

By continuously ventilating the indoor space the ERV-IC deters the buildup of allergens, mould, dust mites and other chemical pollutants when the building is sealed providing a healthier living and working environment. The counter flow enthalpy heat exchanger will reclaim up to 75% of the energy from the exhaust air saving 75% of the cost to heat or cool the outdoor air to the internal temperature and condition.

 

Construction & Installation
  • Filters are not provided with the ERV-IC units but are required to be fitted by the installer to the supply and return ducts 
  • ERV-ICs less than 600 l/s access fans by removing the duct connections. Larger units have underside access panels located beneath each fan
  • The units’ low profile design makes it ideal to fit into tight ceiling spaces
  • The units can be installed to ventilate one or more rooms in the building
  • The size of the ERV-IC is dependent on the volume and use of the space to be ventilated
 


Product Brochure
(100 L/s - 900 L/s)


 
Technical Specifications
(100 Lls - 900 L/s) 


Sound Pressure
Level Data
 


Installation &
Maintenance
Manual

 

 

 

A fully ducted fresh air unit designed to be used in
conjunction with conventional air conditioners to improve air quality and reduce fresh air load.

Air to air enthalpy or sensible heat exchanger
reduces outdoor air load by 75%.

              